How Many Desks Can I Fit In My Office?

How Many Desks Can I Fit In My Office?

To work out how many desks you can fit in your office, divide the usable floor area by about 10 m² per person. That’s the planning standard recommended by the British Council for Offices, and it leaves room for walkways, storage and somewhere to meet.

Then check two things: that the room meets HSE’s minimum space per person, and that the desks really fit on a plan. This guide walks through both, with worked examples.

Quick answer: floor area in m² ÷ 10 = a comfortable number of desks. For the number of people who normally work in the room, never go above room volume in m³ ÷ 11, which is HSE’s minimum. A 30 m² room with a 2.5 m ceiling fits about three desks comfortably, and no more than six people normally working in it.

How many desks can I fit? The quick calculation

You need a tape measure and three numbers: the room’s length, width and ceiling height.

  1. Floor area: length × width, in metres.
  2. Comfortable number of desks: floor area ÷ 10. The British Council for Offices recommends 10 m² per person for general office space.
  3. Upper limit: length × width × height, then ÷ 11. HSE’s workplace guidance sets a minimum of 11 cubic metres per person. Count any height over 3 m as 3 m.

The first number is a sensible target. The second is HSE’s minimum space per person turned into a headcount, so don’t go past it. HSE says even that may not be enough, depending on the layout and the work.

Worked example: a 6 m by 5 m office

Say the room is 6 m long, 5 m wide, with a 2.5 m ceiling.

  • Floor area: 6 × 5 = 30 m². At 10 m² per person, that’s three desks.
  • Volume: 30 × 2.5 = 75 m³. Divided by 11, that’s 6.8, so six people at most.

So plan for three desks, and treat six people as the most HSE’s minimum allows. The HSE figure counts the people who normally work in the room, and these workplace rules don’t cover people working from their own homes.

Worked layout: where the three desks go

Now check the three desks really fit. Here’s one way to lay out the same 6 m by 5 m room, with the door at one end of a 6 m wall.

  • Desks: three 1400 × 800 mm desks side by side along the other 6 m wall. Together they take 4.2 m of wall, which leaves 1.8 m at the end for a tall cupboard.
  • Chair zone: allow about 1.2 m behind the desks, a common rule of thumb for room to push back and for someone to pass. Measure your own chairs to check it.
  • Depth used: 0.8 m of desk plus 1.2 m behind it is 2 m. That leaves a 3 m strip on the door side of the room.
  • The rest: the 3 m strip holds the way in, a small meeting table and printer, with a clear route to the door.

The 10 m² per person already includes that walkway, storage and meeting space. So don’t add a separate allowance for them on top, or you’ll count them twice.

How many desks in 1,000 square feet?

1,000 square feet is about 93 m². At 10 m² per person, that’s about nine desks.

The BCO now treats 8 m² per person as a special case for exceptional situations. At that density, the same floor holds about 11. With a 2.5 m ceiling, the 11 m³ rule caps it at 21 people.

Why 10 m² per person isn’t all desk

The 10 m² figure covers the whole usable floor, not just the desk. It includes walkways, storage, printers, a kitchen corner and space to meet.

If your kitchen and meeting room are elsewhere, a room used only for desks can hold more people than the 10 m² sum suggests. It still has to stay under the 11 m³ limit, and the desks still have to fit on a plan.

Check it on a plan before you buy

A quick sum tells you roughly how many desks to aim for. A plan tells you whether they fit.

  1. Draw the room to scale on squared paper. Mark doors, windows, radiators, sockets and pillars.
  2. Split an odd-shaped room into rectangles and measure each one. Note alcoves and recesses: a deep one can take a compact desk or a storage unit.
  3. Check the ceiling. Mark any low beams, sloping ceilings or bulkheads, and don’t put a desk where someone can’t stand up straight.
  4. Draw each desk at its real size. Our Start and One desks, for example, run from 800 to 1800 mm wide and are 600 or 800 mm deep. As a rule of thumb, allow at least 800 mm of desk width per person.
  5. Add a chair zone behind each desk. Measure it by sitting at a desk and pushing back to stand up. Around 1.2 m between rows of desks is a common starting point.
  6. Check the legroom. With pedestals and kit in place, each person should still be able to sit comfortably, stretch their legs and change position.
  7. Add walkways to the door and between rows, and keep the route out clear.
  8. Think about windows and doors. Desks side-on to a window get daylight without glare on the screen, and nobody wants to sit in the swing of a door.

Our guide to how much space to leave between desks explains the chair zone and walkways in more detail.

Desk spacing at a glance: at least 11 cubic metres of room per person, 10 square metres of floor per person as a planning standard, measure your chair's push-back space, and keep walkways and exits clear.
UK law sets no fixed gap between desks. HSE's code of practice sets a minimum of 11 cubic metres of room per person, and the British Council for Offices plans on 10 m² of floor per person. Measure the space your chair needs and keep a clear walkway behind it.

Desk layouts that fit more people

The type of desk changes how many fit, even in the same room. These layouts make the most of the floor.

  • Bench desks. Two to ten people share one frame, back to back, with no gaps between desks. See our office bench desks.
  • Narrow desks. At 600 mm deep instead of 800 mm, each desk gives 200 mm back to the room. See our narrow desks.
  • Corner desks. In some rooms an L-shaped or crescent desk makes good use of a corner, giving one person a long run of worktop. Check its footprint on your plan. See our corner office desks.

Rows, clusters or benches: which suits your team?

Layout Suits Trade-off
Rows of single desks Long, narrow rooms; people who mostly work alone Clear sightlines and easy to talk to the person next to you, but uses more floor per person than benches
Clusters of four Teams who talk to each other all day Good for collaboration, noisier for people who need to focus
Bench desks The most people in the space; teams who talk all day Least floor per person, but little privacy or storage at each place
L-shaped or corner desks Managers and people with lots of kit or paper; grouped together, a team area More worktop per person, so fewer desks in the room
Hot desks (shared) Teams who aren’t all in every day People choose or book a desk each day and may sit near different colleagues, but need somewhere for their own things

The work itself changes the space each person needs. Someone with two screens and paperwork needs a wider desk than someone on a laptop. People on the phone all day are better a little apart, or near a booth or quiet room. If clients visit, plan a meeting table or room rather than meeting at the desks.

Group people by team, so those who work together sit together. Keep the equipment they share, such as the printer, close to them but out of the walkways.

Spacing is a trade-off, too. Desks close together make quick chats and swapping ideas easy, but bring more distraction. More space between desks gives privacy and suits work that needs concentration. Where you can’t add space, add separation:

  • Desk screens or partitions between neighbours. See our desk screens.
  • Acoustic panels where conversations carry.
  • Plants between desks, allowing for their footprint and keeping walkways clear.

If teams work on group projects, give them a collaboration area with a shared table or desk. Count its floor space before you count the desks.

Plan for the busiest day, and for growth

If not everyone is in every day, you may need fewer desks than people. Count how many sit at a desk on your busiest day, not how many are on the payroll.

Then add the people who aren’t on the payroll yet:

  • Planned hires over the next year or two.
  • Visitors who need a desk, such as staff from another site or regular contractors.

Mark where those extra desks would go on your plan now, so a new starter doesn’t mean a rearrangement. Choose a desk range you can buy more of later in the same size and finish, and modular desks that can be moved or added to.

If people share desks, agree simple rules, such as booking a desk and clearing it at the end of the day. Give everyone somewhere for their own things, since they won’t have a pedestal of their own. Lockers do that job: see our guide to buying office lockers.

How much office space per person in the UK?

There are two figures to know. One is HSE’s minimum, the other a planning standard.

Figure What it is Source
11 m³ per person Minimum room volume in HSE’s code of practice for the workplace regulations. With a 2.5 m ceiling, that’s 4.4 m² of floor. HSE
10 m² per person Recommended design standard for general office space British Council for Offices
8 m² per person High density, now a special case for exceptional situations British Council for Offices

There’s no UK rule for a minimum desk size or a fixed gap between desks. The regulations ask for enough space: each person must be able to move and change position at their workstation.

Plan the storage too

Storage takes floor, so plan where it goes before you count desks. Good storage also keeps documents, supplies and personal things off the desks, so each worktop stays free for work. Plan space for:

  • documents, in filing units or cupboards;
  • shared office supplies, such as paper and stationery, in one cupboard;
  • personal things, in pedestals or lockers.

A pedestal under each desk uses space you already have. Tall cupboards along a wall store more for their footprint than low units dotted around the room. Built-in cabinets can use an alcove, if the room allows.

Shelving units keep files and supplies within reach. Adjustable shelves can move up or down to fit items of different sizes, and change as your needs change. Choose storage in finishes and colours that go with your desks, so the office looks planned. See our office pedestals and office cupboards.

Start with the sum, finish with the plan

Divide the floor area by 10 for a comfortable target, check the room volume against 11 m³ per person, then prove it on a scale plan.

When you know the number, our guide to how deep an office desk should be will help you pick a size, and our office desk buyer’s guide covers the rest of the choice. And if you’d like a second opinion on desk sizes, our friendly team is happy to help.

Related Post